|
NEVER expose your In-Line Duct Fan to
airflow temperatures exceeding 140°F (60°C).
-
Make sure all electrical wiring conforms to all
applicable codes and standards. If you are not familiar with electrical
installations, consult a qualified electrician.
-
Never use an In-Line Duct Fan for dryer venting.
-
Never connect the High and Low speed wires of a
2-speed In-Line Duct Fan together.
Why do I have a room that is always
too cold?
Your problem room may be located far from the furnace. Friction in the long
duct reduces airflow to the register in that room, thus delivery of heated
air. Also, perhaps the room is over an unheated garage or the duct is simply
too small (undersized) to get enough heated air to that room. Remember too,
when you are delivering heated air to a room, that air has to have a way to
get out of that room. Otherwise there will be no air circulation. Does the
room have an air return register? If not, is the door of that room kept
closed, stopping air circulation?
Why do I have a room that is always
too hot ?
The room that you have a cooling problem with may be far away from the
central air system. Long duct runs cause reduction in airflow, plus, the
cooled air may have heated up before it gets to the problem room. Perhaps
the problem run is to a room on the South side of the house, which has a
large window, catching a lot of summer heat.
Chances are that your 'hot' rooms are on the second level of your home. You
see, cooled air is dense and heavy. It doesn't like to flow upstairs. This
is a very common problem, worsened by undersized ductwork and
inaccessibility of those ducts. Particularly for upstairs cooling problems,
select the largest fan you can fit and use duct diameter expanders &
reducers to adapt to the ducts already in place.
What boost can I expect from an
In-Line Duct Fan?
A standard floor or wall register is normally fed by a 6" diameter duct. You
would like to boost the airflow from that register because you have a room
that is usually cold in the winter or hot in the summer.
The airflow from that register may be as low as 20 or 30 Cubic Feet of air
per minute.
Expect this particular example to have double the airflow when an In-Line
Duct Fan is installed.
What temperature difference does
boosted airflow make?
This is dependent on a host of variables. How well insulated is the room?
What heat gain in the summer through a window? How far is the register from
the furnace? Is this room over an unheated garage? Etc.
Here is an example:
During the winter heating season, you need a room about 4 °F warmer than it
is. To achieve this you will need 11% more airflow out of the register(s) in
that room assuming that your furnace runs 60 minutes out of the hour.
If your furnace runs 20 minutes out of the hour on a cold winter day, that
is 1/3 of an hour. You will need 3 times the 11% or 33% boost. In most
applications, an In-Line Duct Fan will boost up to 80%. Thus, well up to the
task of warming up a room.
How loud will the installed fan be?
Suncourt fans are rated between 50-60 dBA.
How much power does an In-Line Duct
Fan use?
Example: The DB206P, 6" diameter In-Line Duct Fan is rated at 0.35 Amp.
For a 120 Volt product, that is 0.35 x 120 = 42 Watt.
This is the maximum motor STARTING Watts. Once the fan runs, the actual
wattage is 27 Watts. Like a small light bulb. In the Suncourt product
specifications section, Inductors are listed by Amperage. As a rule of
thumb, running Amperage is about 60% of the listed (start) Amperage.
So, to figure it out: Listed Amperage times Voltage (120 Volt) equals
startup Watts.
Actual running Watts are about 60% of that.
What type of motors are used in
Suncourt products?
The electric motors used in Suncourt products are C-Frame two-pole motors,
Class B, Thermally Protected, sleeve bearings and synthetic lubricant. The
exceptions are the 400 Series In-Line Duct Fans which have 4-pole, Class B,
Thermally Protected motors with sleeve bearings and synthetic lubricant.
Can I use a rheostat or fan speed
control with an In-Line Duct Fan?
No. A rheostat lowers the voltage supplied to the fan motor. This will cause
the motor to overheat and the Thermal Protector will open, destroying the
motor.
A solid-state fan speed control could be used. The problem is that such a
control allows the fan to be adjusted to very low RPM's. Since the electric
motor needs air flowing over it for cooling, adjusting to too low a RPM will
cause the motor to overheat. That will cause the Thermal Protector to open,
destroying the motor and voiding the Warranty. Since the speed the motor is
adjusted by the user and is not under the control of Suncourt, we advise
against using a solid-state motor speed control.
What does Thermally Protected mean?
A thermally Protected motor contains a fuse that will cut off power to the
motor should the motor temperature exceed a safe limit. All Suncourt
electric motors are Thermally Protected.
What are the fan blades made of?
The 4"-8" In-Line Duct Fan are equipped with Polycarbonate fan blades. (A
high strength superior material as used for jet fighter canopies). The
10"-14"In-Line Duct Fans have aluminum fan blades.
How many Inductor fans can I install?
We recommend that you do not install more than 2 In-Line Duct Fans per 8
registers in your air distribution system.
Two boosters will not appreciably affect the airflow to the remaining
registers.
If you install more than 2 In-Line Duct Fans per 8 registers, you may be
lowering the airflow from a register in some other room in your home, thus
creating temperature problems there.
Will an Inductor always double
airflow from any register?
No. An In-Line Duct Fan will boost airflow more to a poorly performing
register (which is the register needing help) than to a register that
already has good airflow. As stated before, a poorly performing register may
have double the airflow with an In-Line Duct Fan. A well performing register
may have a 30% to 50% percent increase in airflow.
What is the difference between Free
Air and Boosted Air?
Free air is the air volume output from a fan, expressed in Cubic Feet per
Minute (CFM) when the fan is not connected to any ductwork, pipes, louvers
or other items that would interfere with the free flow of air from the fan.
Boosted Air is the maximum airflow that can be passed through an In-Line
Duct Fan in CFM before this fan, installed in a duct, becomes a hindrance to
airflow rather than boosting an existing airflow.
Depending on the specifics of the electric motor and fan blade combination,
Boosted Air can be between 50% to 100% greater than Free Air.
Can I "over boost" a register?
Suncourt In-Line Duct Fans are designed to provide progressive boost. This
means that the airflow is proportionally boosted to the need of a particular
register. Our booster fans are designed to run at a low RPM in free air. At
this RPM, the fan motor runs below the peak torque that can be generated by
the motor. Depending on the air blown into the intake side of the In-Line
Duct Fan, the RPM will adjust itself as needed to provide boost and will
operate at or near peak torque of the electric motor.
In what type of duct can I install an
In-Line Duct Fan?
In-Line Duct Fans are suitable for installation in metal, flexible or high
density pressed fiberglass ducts. The In-Line Duct Fan can be secured to the
duct with screws or a good quality duct tape.
Can I build-in an In-Line Duct Fan,
i.e. drywall or panel over it?
No. The In-Line Duct Fan must always remain accessible for service, cleaning
or repair.
Can I use the In-Line Duct Fan to
vent outside air?
The In-Line Duct Fan has to be protected from rain and excessive moisture.
What is the lowest airflow
temperature for an In-Line Duct Fan?
To maintain good oiling of the motor bearings, we recommend a minimum
temperature of 40°F (4°C).
What do I typically need for
electrical installation?
You will need a small electrical box to mount on the In-Line Duct Fan.
We recommend #8 self piercing sheet metal screws, ½" to 5/8" long. Be sure
these screws do not touch the fan blade or the electric motor.
For this box you will need a power supply strain relief to mount in a
"knockout" in the electrical box.
Choose the power cable to conform to the applicable codes and standards. The
staff at your favorite Home Center can recommend these materials to you.
Where do I get power from for the
In-Line Duct Fan?
Here you have a number of options.
The easiest way to power your In-Line Duct Fan for automatic ON/OFF
operation with both your furnace and air conditioner is to use the
Suncourt DuctStat. Please view the
DuctStat section of these
FAQ's.
You may power the In-Line Duct Fan via a standard wall switch for manual
ON/OFF operation. Running an In-Line Duct Fan continuously will not
appreciably affect the life of the fan.
The next best is to connect to the wiring of your furnace. You must connect
to the wire that provides power to your furnace blower. Consult the furnace
wiring diagram, usually located on the inside of the panel covering the main
furnace blower. Again make sure that all wiring conforms to all applicable
standards and codes.
Also check that your furnace blower motor has a 110-120 Volt AC motor. Some
larger furnaces have 220-240 Volt AC motors. Some of the newest high-end
furnaces have DC motors. Do not connect the In-Line Duct Fan to either the
220-240 Volt AC or the DC type.
.
Because of the numerous variations in furnace wiring, Suncourt
cannot advise you on the hookup.
Can I wire my two-speed In-Line Duct
Fan to run on High or Low speed?
Yes, but first this warning. NEVER connect the High and Low speed
wires together.
The motor wiring will burn out in a matter of seconds, permanently
destroying the unit. Wire to operate either on High speed or Low speed.
Never both.
You may use a Single Pole, Double Throw "ON-OFF-ON" toggle, rocker or other
switch to wire for High or Low speed operation. This switch must be rated
for 125 Volt AC, 10 Amp minimum. Now you can switch your 2-speed Inductor
from High to Low speed and have a center OFF position. Connect the supply
power to the C (common) terminal, the High speed wire from the motor to the
terminal marked 1 and the Low speed wire from the motor to the terminal
marked 2. Make sure that the wiring and enclosure for this switch conform to
all applicable standards and codes.
Is the In-Line Duct Fan safe?
The In-Line Duct Fans have been rigorously tested to the Standards of
Underwriters Laboratories Inc. and proudly display the Listing symbols of
both Underwriters Laboratories Inc. (UL®) and Intertech Testing Services
Ltd. (ETL®). All Inductors have Thermally Protected electric motors. |